KONICA MINOLTA

Isik Ölçüm Cihazi

Konica Minolta Illuminance Meter-T-10

Specifications Principal Specifications T-10 Series Model Illuminance meter T-10 Illuminance meterT-10M Type Multi-function digital illuminance meter with detachable receptor head Receptor Silicon photocell Relative Spectral Response* Within 6% (f1´) of the CIE spectral luminous efficiency V (λ) Cosine Correction Characteristics Within ±1% at 10° ; Within ±2% at 30° ; Within ±6% at 50° ; Within ±7% at 60° ; Within ±25% at 80° Illuminance units Lux (lx) or foot candles (fcd) (switchable) Measuring range Auto range (manual 5 range at the time of analog output) Measuring function Illuminance(lx). illuminance difference(lx). illuminance ratio(%). integrated illuminance(lx·h). integration time(h). average illuminance(lx). Measuring range Illuminance 0.01 to 299,900 lx 0.001 to 29,990 fcd Integrated illuminance 0.01 to 999,900 × 103 lx·h 0.001 to 99,990 × 103 fcd·h / 0.001 to 9999 h User calibration function CCF(Color Correction Factor) setting function Accuracy ±2% ±1digit of displayed value (based on Konica Minolta standard) Temperature/humidity drift Within ±3% ±1digit (of value displayed at 20°C/68°F ) within operating temperature/humidity range Digital output RS-232C Analog output 1mV/digit,3V at maximum reading; Output impedance: 10KΩ; 90% response time: FAST setting: 1ms, SLOW setting: 1s Display 3 or 4 Significant-digit LCD with back-light illumination Operating temperature /humidity range -10 to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature /humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation Power source 2 AA-size batteries / AC adapter (optional) Battery life 72 hours or longer (when alkaline batteries are used) in continuous measurement Dimensions 69 × 174 × 35 mm (2-6/16×6-14/16×1-7/16 in.) Main body : 69 × 161.5 ×30 mm (2-6/16×6-6/16×1-3/16 in.) Receptor : Ø 16.5 × 12.5 (Ø 11/16 × 1/2 in.) Cord length : 1 m ( 3.3 in.) Weight 200 g (7.0 oz.) without battery 205 g (7.2 oz.) without battery Standard accessories Ø 3.5 mm (Ø 1/8 in.) subminiature plug for analog output ; Receptor cap ; Neck strap ; Case ; Battery Ø 3.5 mm (Ø 1/8 in.) subminiature plug for analog output ; Neck strap ; Case ; Battery Optional accessories Receptor head ; Adapter for Multi-point ; AC Adapter ; Data processing software  

Konica Minolta Incident Color Meter CL-200

Specifications Principal Specifications CL-200 Model Incident Color Meter CL-200 Relative spectral response Closely matches CIE standard observer curves x–(λ), y–(λ), and z–(λ) Within 8% (f1') of the CIE spectral luminous efficiency V(λ) Receptor Silicon photocell Measurement functions Tristimulus values: XYZ   Chromaticity coordinates: Ev xy, Ev u'v'   Correlated color temperature: Ev, Tcp, Δuv   Color difference: Δ(XYZ), Δ(Ev xy), Δ(Ev u'v'), ΔEvΔu'v' (One target color)   Other functions User calibration function, Data hold function, Multi-point measurement (2 to 30 receptors) Measuring range 0.1 to 99,990 lx, 0.01 to 9,999 fcd (Chromaticity: 5 lx, 0.5 fcd or above) in four automatically selected ranges Accuracy Ev: ±2%, ±1 digit of displayed value (based on Konica Minolta standard) xy: ±0.002 (800 lx, Standard Illuminant A measured) Repeatability Ev: 0.5% ±1 digit (2σ) xy: ±0.0005 (800 lx, Standard Illuminant A measured) Temperature drift Ev: ±3%, ±1 digit of displayed value xy: ±0.003 Humidity drift Ev: ±3%, ±1 digit of displayed value xy: ±0.003 Response time 0.5 sec. (continuous measurement) Digital output RS-232C Display 4 Significant-digit LCD with back-light illumination Operating temperature/humidity range -10 to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature/humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation Power source 2 AA-size batteries / AC adapter (optional) Battery life 72 hours or longer (when alkaline batteries are used in continuous measurement Dimensions 69 × 174 × 35 mm (2-3/4 × 6-7/8 × 1-3/8 in.) Weight 215 g (7.6 oz) not including batteries Standard accessories Soft case, lens cap, neck strap, batteries Optional accessories Additional receptors, Adapter Unit for Main Body T-A20; Adapter Unit for Receptor Head T-A21; AC Adapter AC-A10 (AC-A10N in North America); Data Management Software CL-S1w; Printer Cable T-A12; Connecting Cable T-A11 (for PC); Hood CL-A11; Hard Case CL-A10  

Konica Minolta Luminance Meter-LS-100 & LS-110

Specifications Principal Specifications LS-100/LS-110 Model Luminance Meter LS-100 Luminance Meter LS-110 Type SLR spot luminance meter for measuring light-source and surface brightness Acceptance angle 1° 1/3° Optical system 85mm f/2.8 lens; SLR viewing system; flare factor less than 1.5% Angle of view 9° Focusing distance 1014mm (40 in.) to infinity Minimum measuring area Ø 14.4 mm Ø 4.8 mm Receptor Silicon photocell Relative Spectral Response* Within 8% (f1´) of the CIE spectral luminous efficiency V (λ) Response time FAST: Sampling time: 0.1s, time to display: 0.8 to 1.0s; SLOW: Sampling time: 0.4s, time to display: 1.4 to 1.6s Luminance units cd/m2 or fL (switchable) Measuring range FAST: 0.001 to 299,900 cd/m2 (0.001 to 87,530fL) SLOW: 0.001 to 49,990 cd/m2 (0.001 to 14,590fL) FAST: 0.01 to 999,900 cd/m2 (0.01 to 291,800fL) SLOW: 0.01 to 499,900 cd/m2 (0.01 to 145,900fL) Accuracy 0.001 to 0.999 cd/m2 (or fL): ±2% ±2 digits of displayed value 1.000 cd/m2 (or fL) or greater: ±2% ±1 digit of displayed value 0.01 to 9.99 cd/m2 (or fL): ±2% ±2 digits of displayed value 10.00 cd/m2 (or fL) or greater: ±2% ±1 digit of displayed value (Illuminant A measured at ambient temperature of 20 to 30°C/68 to 86°F) Repeatability 0.001 to 0.999 cd/m2 (or fL): ±0.2% ±2 digits of displayed value 1.000 cd/m2 (or fL) or greater: ±0.2% ±1 digit of displayed value 0.01 to 9.99 cd/m2 (or fL): ±0.2% ±2 digits of displayed value 10.00 cd/m2 (or fL) or greater: ±0.2% ±1 digit of displayed value (Measurement subject: Illuminant A) Temperature/humidity drift Within ±3% ±1 digit (of value displayed at 20°C/68°F) within operatingtemperature /humidity range Calibration mode Minolta standard/user-selected standard (switchable) Color correction factor Set by numerical input; range: 0.001 to 9.999 Reference luminance 1; set by measurement or numerical input Measurement modes Luminance; luminance ratio; peak luminance or luminance ratio Display External: 4-digit LCD with additional indications Viewfinder: 4-digit LCD with LED backlight Data communication RS-232C; baud rate: 4800bps External control Measurement process can be started by external device connected to data output terminal Power source One 9V battery Power consumption While measuring button is pressed and viewfinder display is lit: 16 mA average While power is on and viewfinder display is not lit: 6 mA average Operating temperature/humidity range 0 to 40°C, relative humidity 85% or less (at 35°C) with no condensation Storage temperature /humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation Dimensions 79×208×150 mm (3-1/8×8-3/16×5-7/8 in.) Weight 850 g (30 oz.) without battery Standard accessories Lens cap; Eyepiece cap; ND eyepiece filter; 9V battery; Case  

Konica Minolta UV Radiometer-UM-10

Introduction Hand-held and easy to use UV Radiometer for various applications The recording of the strength of ultraviolet radiation and radiation is the task of the Konica Minolta UV radiometer. UV radiation is used in many areas of product development and production, such as food technology, agricultural technology, or in the production of semiconductors. UV radiation is even used in medicine and cosmetics; the best-known application may be the sun bed. UV radiometers capture this radiation and help with control as well in research and development. Background knowledge The strength of UV radiation is measured in W/m2 (or μW/cm2) and is equivalent to the illumination strength in lux, which is measured with lux meters. It indicates how much UV radiation strikes a defined surface. The radiation indicates the amount of UV radiation in J/m2 (Joule per square meter) or mJ/cm2 that hits a surface over a specific time frame and is the radiant physical equivalent to exposure. UM-10 Display unit The UM-10 is a small, handy, modularly constructed instrument with a choice of three receptor heads to record UV radiation in the spectral area of 220 nm to 480 nm. Within this wide measurement range of 0.1 to 199,900 μW/cm2, the UM-10 switches the measurement range automatically and indicates readings on the large LCD. A digital (RS-232C) as well as an analogue output enables the measurement values to be exported to a PC and other instruments. Depending on the measurement task and/or the spectral area to be measured, an appropriate receptor head is chosen and attached to the basic UM-10 unit. Receptor Head UM-250 The receptor head UM-250 captures "hard" UV radiation in the area of 220 nm - 300 nm with a centre of gravity wavelength of about 250 nm. Receptor Head UM-360 The receptor head UM-360 captures "soft" UV radiation in the area of 310 nm -400 nm with a centre of gravity wavelength of about 365 nm. Receptor Head UM-400 The receptor head UM-400 captures UV and blue radiation in the area of 360 nm - 480 nm with a centre of gravity wavelength of about 415 nm.